Thermostatic Expansion Valve: Removal
WARNING:
Eye protection must be worn.
- Remove the climate control assembly. See Auxiliary Climate Control Assembly .
- Remove the TXV assembly.
- Disconnect the electrical connector.
- Remove the 2 bolts.
- Remove the 2 screws.
- Discard the O-ring seals.
CAUTION:
Before disconnecting or removing the components, ensure the area around the joint faces and connections are clean. Plug open connections to prevent contamination.
NOTE:
The receiver drier need only be changed under the following circumstances: There is dirt in the refrigerant circuit (eg. compressor seizure). The system is leaking and refrigerant has been lost to atmosphere. Refrigerant circuit has been open more than 24 hours due to repair.