Pinpoint Test B: Roof Opening Panel - Inoperative
B1: INOPERATIVE
- Perform the manual roof opening panel initialization procedure REFER to: Power Roof Opening Panel Initialization . Check for correct roof opening panel operation
Does the roof opening panel operate correctly?
Yes:
No further action required
No:
GO to B2 .
B2: FUSE
- Refer to the electrical circuit diagrams and check the fused link to the roof opening panel motor
Is the fused link (VBATT) circuit to the roof opening panel motor intact?
Yes:
GO to B3.
No:
The fused link to the roof opening panel motor has failed. Refer to the electrical circuit diagrams and check the circuit - VBATT - between the fused link and the roof opening panel motor for short circuit to ground. Replace the fused link or repair the circuit as required. Perform the manual roof opening panel initialization procedure REFER to: Power Roof Opening Panel Initialization . Check for correct operation, If correct no further action required
B3: SWITCH CONNECTOR
- Access to the connector for the front overhead console REFER to: INSTRUMENT PANEL AND CONSOLE
- Refer to the electrical circuit diagrams and check the roof opening panel switch terminals and housing for location and condition
Are the roof opening panel switch terminals and housing located correctly and in good condition?
Yes:
GO to B4 .
No:
Correctly relocate or replace any roof opening panel switch connector terminals as required. Perform the manual roof opening panel initialization procedure REFER to: Power Roof Opening Panel Initialization . Check for correct operation, If correct no further action required
B5: SWITCH - CIRCUIT CHECK
- Refer to the electrical circuit diagrams and locate the open and close circuits between the roof opening panel motor and the roof opening panel switch, monitor the voltage on each circuit as the switch is operated
Do both open and close switch circuit voltages change from greater than 7 volts to less than 1 volt when the roof opening panel open or close switches are pressed?
Yes:
GO to B8 .
No:
GO to B6 .
B6: SWITCH - CIRCUIT CHECK 2
- Refer to notes above
Did the voltage remain low (less than 1 volt) ?
Yes:
GO to B7 .
No:
The voltage remained high (greater than 7 volts) refer to the electrical circuit diagrams and check the roof opening panel switch circuit for fault. Repair as required. Perform the manual roof opening panel initialization procedure REFER to: Power Roof Opening Panel Initialization . Check for correct operation, If correct no further action required
B8: MOTOR - FAILURE
- Uninstall the motor from the roof opening panel REFER to: Roof Opening Panel Motor .
- Operate the roof opening panel using the roof mounted switch
When operating the switch, does the motor operate?
Yes:
GO to B9 .
No:
Replace the roof opening panel motor REFER to: Roof Opening Panel Motor . Check for correct operation, If correct no further action required
B9: MANUAL - ROOF OPERATION
- Reinstall the roof opening panel motor to the roof opening panel frame REFER to: Roof Opening Panel Motor .
- Using a large flathead screwdriver applied to the motor, operate the roof opening panel through all possible positions (slide open / slide close / tilt open / tilt close)
Can the roof opening panel be manually operated through all possible positions?
Yes:
Install a new roof opening panel module REFER to: Roof Opening Panel Module . Check for correct operation, If correct no further action required
No:
GO to B10 .
B10: GLASS PANEL - REMOVAL
- Remove the glass panel from the roof opening panel REFER to: Roof Opening Panel Glass
Can the glass panel be removed?
Yes:
GO to B11 .
No:
Contact dealer technical support
B11: GLASS PANEL REMOVED
- Carry out visual and manual inspection of the rail(s) for debris
Are the rail(s) free from debris?
Yes:
GO to B12 .
No:
Clear any obstructions from the rails. Apply grease (KP 1N-30 or ISO-L-X-CDBE1) to the areas shown. Then, GO to B12 .
B12: LIFTER ARMS - CONDITION
- Carry out visual inspection of the lifter arms
for cracks or damage (pieces broken)
Are the lifter arms cracked or damaged?
Yes:
Replace the lifter arms. Perform the manual roof opening panel initialization procedure REFER to: Power Roof Opening Panel Initialization . Check for correct operation, If correct no further action required
No:
GO to B13 .
B13: REAR MECHANISM - CONDITION
- Carry out visual inspection of the rear mechanism
Are the rear mechanisms free from cracking and damage?
Yes:
GO to B14 .
No:
Install a new roof opening panel REFER to: Roof Opening Panel . Check for correct operation, If correct no further action required
B14: GLASS PANEL - RE-ASSEMBLY
- Re-assemble the glass panel onto the roof opening panel REFER to: Roof Opening Panel Glass .
- Perform the manual roof opening panel initialization procedure REFER to: Power Roof Opening Panel Initialization .
- Check for correct roof opening panel operation
Does the roof opening panel operate correctly?
Yes:
No further action required
No:
Contact dealer technical support