Pinpoint Test E: Roof Opening Panel - Bounce Back
E1: INITIALIZATION
- Perform the manual roof opening panel initialization procedure REFER to: Power Roof Opening Panel Initialization . Check for correct roof opening panel operation
- Operate the roof opening panel through all possible positions (slide open / slide close / tilt open / tilt close) using the roof mounted switch
- 3 Operate the roof opening panel one touch function five times in succession using the roof mounted switch
Does the roof opening panel operate correctly five times in succession?
Yes:
No further action required
No:
GO to E2 .
E2: GUIDES - INSPECTION
- Carry out visual inspection of the guides
Are the guides free from debris and obstruction?
Yes:
GO to E3 .
No:
Remove any debris or obstruction. Check for correct operation. (1) If correct no further action required. (2) If customer concern is still evident GO to E3 .
E3: SIDE COVERS
- Carry out visual inspection of the side covers attached to the glass panel
Are the side covers bent or damaged?
Yes:
Replace the glass panel REFER to: Roof Opening Panel Glass . Check for correct operation. (1) If correct no further action required. (2) If customer concern is still evident GO to E4 .
No:
GO to E4 .
E4: WIND DEFLECTOR
- Carry out visual inspection of the wind deflector
Is the wind deflector damaged or incorrectly located?
Yes:
Re-install or replace the wind deflector as required. Check for correct operation. Check for correct operation. (1) If correct no further action required. (2) If customer concern is still evident contact dealer technical support
No:
If concern still evident contact dealer technical support