Symptom Driven Diagnostics (SDD) Displays Update Icon And Reduced Functionality If Not Updated (SSM74882)
Reference number: SSM74882
SYMPTOM DRIVEN DIAGNOSTICS (SDD) DISPLAYS UPDATE ICON AND REDUCED FUNCTIONALITY IF NOT UPDATED
TECHNICAL SERVICE BULLETIN
| LAND ROVER: | Defender/L316; Discovery Sport/L550; LR2/L359; LR3/L319; LR4/L319 2010 → Onwards; Range Rover/L322; Range Rover/L405; Range Rover Evoque/L538; Range Rover Sport/L320; Range Rover Sport/L494; Range Rover Velar/L560 |
| SERVICE CATEGORY: | Diagnostic Software Hardware |
ISSUE
Symptom Driven Diagnostics (SDD) is displaying various messages suggesting that the software is out of date.
- A software update Icon in the top right corner of the page, (when trying to update the software you receive a "No update available" message).
- A message is displayed stating that SDD will have reduced functionality if not updated.
CAUSE
SDD software has not been released to market in the scheduled time, as no SDD software content has been required.
There were enhancements released within SDD 159.07 to change the mechanism and timing due to the current situation and no SDD releases. Further investigation has found another timing setting concern linked to the download icon.
ACTION
This workaround will load a software file to the Jaguar Land Rover Approved Diagnostic Equipment using the Manual Patch Update process.
This Manual Patch will stay on the JLR Approved Diagnostic Equipment.
To apply the Manual Patch please, complete the instructions carefully.
- Restart the JLR Approved Diagnostic Equipment
- Make sure Symptom Driven Diagnostics (SDD) and PATHFINDER are closed. Then select the 'Manual Patch' Icon on the Application Launcher screen. You will see a pop-up for the Manual Patch downloader.
- Enter 'MP_SDD_D0040 ' in the 'Patch Name' field.
- Select 'Start' and the Manual Patch will download.
- Select 'Yes' when the patch download is finished.
- Start a new SDD session
- Confirm download icon in top right corner is no longer present
If this Manual Patch fails to correct the concern, a Diagnostic EPQR (for Retailers) or email to retailer@jaguarlandrover.com (for Independant Operators) should be submitted, using the manual patch number as a reference and quoting the communication reference number that the patch was taken from.
PERMANENT CORRECTIVE ACTION
Once the permanent corrective action has been released, this communication and Manual Patch will be expired. An updated communication will be released detailing which JLR Approved Diagnostic Equipment version includes the permanent corrective action.