| Mirrors do not defrost/washer jets freeze |
- Fuse fault
- Heated washer jets / heated mirrors circuit short circuit to ground, open circuit, high resistance
- Automatic Temperature Control Module (ATC) fault
|
- Check the fuses
- Refer to the electrical circuit diagrams and test the heated washer jets / heated mirrors circuit for short circuit to ground, open circuit, high resistance
- Using the manufacturer approved diagnostic system, check the Automatic Temperature Control Module (ATC) for related DTCs and refer to the relevant DTC index
|
| Mirrors inoperative in one or more directions |
- Door mirror mechanical failure
- Door mirror circuit short circuit to ground, short circuit to power, open circuit, high resistance
- Driver/Passenger Door Module (DDM/PDM) fault
|
- Operate the mirror switch and listen for the motor(s). If each motor operation is audible, check the mechanical condition of the mirror and linkages
- Refer to the electrical circuit diagrams and test the door mirror circuit for short circuit to ground, short circuit to power, open circuit, high resistance
- Using the manufacturer approved diagnostic system, check the Driver/Passenger Door Module (DDM/PDM) for related DTCs and refer to the relevant DTC index
|
| Memorized mirror position is not resumed |
- Battery voltage below 10.5 volts
- Position not stored
- Switch operated during "one-touch" memory recall
|
- Refer to the relevant section of the workshop manual and test the battery
- Make sure that the desired position is correctly stored
- Make sure that the memory store/recall procedure is being followed
|
| 'Lazy entry' function inoperative |
- Remote transmitter fault (battery, transmitter programming, etc)
- Battery voltage below 10.5 volts
- Position not stored
- Switch operated during "one-touch" memory recall
|
- Check that the remote transmitter operates the central locking
- Refer to the relevant section of the workshop manual and test the battery
- Make sure that the desired position is correctly stored
- Make sure that the memory store/recall procedure is being followed
|