Restraints Control Module (RCM): Removal
WARNING:
It is imperative that before any work is undertaken on the SRS system, the appropriate information is read thoroughly.
WARNING:
Always disconnect both battery cables before beginning work on the SRS system. Disconnect the ground cable first. Never reverse connect the battery.
NOTE:
If the restraints control module (RCM) is to be replaced then T4 must be connected and the correct procedures adhered to, prior to battery disconnection.
NOTE:
If the SRS component is to be replaced, the bar code of the new unit must be recorded.
- Disconnect the battery ground cable. Refer to Specifications article.
- Make the SRS system safe. Refer to Standard Workshop Practices article.
- Remove the floor console. Refer to Floor Console article.
- Remove the restraints control module (RCM).
- Cut the carpet for access.
- Disconnect the 2 electrical connectors.
- Remove the 3 Torx screws.
CAUTION:
Make sure the wiring harness is protected when cutting the carpet.