Pinpoint Test I: Roof Opening Panel - Wind Noise
I1: VERIFY CUSTOMER CONCERN
NOTE:
These tests are to be carried out to determine the cause of the wind noise around the roof opening panel area
- Perform the manual roof opening panel initialization procedure REFER to: Power Roof Opening Panel Initialization .
- Carry out a road test to verify the customer complaint, drive at the speed indicated by the customer
Can the noise be confirmed?
Yes:
If the customer concern is still evident GO to I2 .
No:
No further action required
I2: OPERATION
- Operate the roof opening panel through all possible positions (slide open / slide close / tilt open / tilt close) using the roof mounted switch
Does the roof opening panel operate correctly?
Yes:
GO to I3 .
No:
GO to Pinpoint Test B .
I3: GLASS PANEL ALIGNMENT
- Correctly relocate the glass panel as required. REFER to: Roof Opening Panel Alignment .
- Carry out visual inspection of the glass panel alignment to the roof aperture
Is the alignment correct?
Yes:
GO to I4 .
No:
Contact dealer technical support
I4: GLASS SEAL
- Carry out visual inspection of the glass panel seal
Is the glass panel seal correctly installed?
Yes:
GO to I5 .
No:
Install a new roof opening panel glass REFER to: Roof Opening Panel Glass .
I5: WIND NOISE
- Carry out a road test, drive at the speed indicated by the customer
Is the wind noise still evident?
Yes:
Contact dealer technical support
No:
No further action required